Telecentric F-theta Scanning Lens China | 355nm | 532nm | 1064nm…

Short Description:


Product Detail

Product Tags

Telecentric Laser F-theta Lens Fused Silica and Optical Glass,1064nm, 355nm, 532nm, 10600nm Coating

The impact angle of the telecentric f-theta flat-field mirror is tightly controlled so that the output beam is nearly perpendicular to the working plane at any field-of-view angle. As a result, the roundness, uniformity (X-axis, Y-axis direction), and perpendicularity (Z-axis direction) of the focal point can be greatly improved over the entire marking width. This is why the telecentric f-theta lens has special advantages in precision laser machining and vertical perforation.

Product Picture

Standard F-theta Lens-Optical Glass-3
F-theta Scan Lens China Manufacturer 10600nm
Standard F-theta Lens-Optical Glass

Specification

1064nm Fuced Silica
1064nm Optical Glass
355nm Fuced Silica
532nm Fuced Silica
532nm Optical Glass
1064nm Fuced Silica
Part Number EFL WD Φ in Scan Angle Scan Field Spot Size ΦOutside Max. IA Mount Thread
(mm) (mm) (mm) (mm) (mm) (µm) (mm) (°)
f-32T-1030-1080 32 31.79 10 ±7.6° Φ 8.5   (6 × 6) 6.2 90 1.4 M85 × 1
f-65T-1030-1080 65 80.99 10 ±16° Φ 36   (26 × 26) 12.65 90 0.58 M85 × 1
f-88T-20-1030-1080 88 120.51 20 ±9.5° Φ 28.28   (20 × 20) 8.78 120 1.3 M85 × 1
f-90T-20-1030-1080 90 101.323 20 ±17° Φ 54   (38 × 38) 35 120 1.9 M85 × 1
f-100T-1030-1080 100 142.73 14 ±20.7° Φ 76   (54 × 54) 13.5 120 0.59 M85 × 1
f-100T-1030-1080 100 142.73 14 ±20.7° Φ 76   (54 × 54) 13.5 135 0.59 M85 × 1
f-100T-14-1030-1080 100 130.44 14 ±20° Φ 72   (51 × 51) 13.9 120 0.5 M85 × 1
f-120T-1030-1080 120 168.59 10 ±24° Φ 98   (70 × 70) 23.5 120 3 M85 × 1
f-125T-14-1030-1080 125 153.27 14 ±16.5° Φ 77.7   (55 × 55) 17.39 112 2 M85 × 1
f-125T-20-1030-1080 125 153.27 20 ±18° Φ 70.7  (50 × 50) 12.17 112 1.8 M85 × 1
f-167T-1030-1080 167 215.5 14 ±20.3° Φ 120  (85 × 85) 17 140 3.69 M85 × 1
f-200T-14-1030-1080 200 296.954 14 ±20° Φ 141 (100×100) 27.82 173 2 M85 × 1
f-254T-14-1030-1080 254 376.53 14 ±18° Φ155.5(110×110) 35.3 126 5 M85 × 1
1064nm Optical Glass
Part Number EFL WD Φ in Scan Angle Scan Field Spot Size ΦOutside Max. IA Mount Thread
(mm) (mm) (mm) (mm) (mm) (µm) (mm) (°)
f-100T-1064 100 122.8 15 ±22° Φ 77   (55 × 55) 13 120 2.1 M85 × 1
f-125T-1064 125 139.58 20 ±21.5° Φ 109  (66 × 66) 12 120 3 M85 × 1
f-167T-1064* 167 216.23 20 ±21° Φ 125  (90 × 90) 16.5 140 4.4 M85 × 1
F-170T-30-1064 * 170 209.61 30 ±21° Φ 120  (88 × 88) 11.1 140 4.4 M102 × 1;M112
f-183T-20-1064* 183 219.63 20 ±11.5° Φ 70.7  (50×50) 17.82 113 0.8 M85 × 1
f-210T-30-1064-M95 * 210 279.63 30 ±22° Φ 161 (115×115) 13.69 188 3.3 M95×1
f-210T-30-1064-M102 * 210 279.63 30 ±21° Φ 154(108×108) 13.69 188 3.3 M102×1
f-211T-10-1064-M85 * 211 279.63 10 ±20° Φ 147(104×104) 41.1 150 4.4 M85 × 1
f-315T-14-1064B* 315 432.072 14 ±24.5° Φ 269(190×190) 43.8 270 2.3 M85 × 1
355nm Fuced Silica
Part Number EFL WD Φ in Scan Angle Scan Field Spot Size Φ Outside Mount Thread
(mm) (mm) (mm) (mm) (mm) (µm) (mm)
f-30T-355 30 35.347 10 ±10.5º Φ 8.5   (8 x 8) 1.95 47.4 M39 × 1
f-32T-355B 32 26.34 10 ±7.6º Φ 8.5   (1 x 1) 3.2 90 M85 × 1
f-60T-355 60 73.65 10 ±16º Φ 31   (22 × 22) 11.5 90 M85 × 1
f-65T-355 65 81.106 10 ±9.4º Φ 21.2  (15 x 15) 4.2 94 M85 × 1
f-70T-355 73.9 91.35 10 ±16º Φ 40   (28 x 28) 4.5 90 M85 × 1
f-100T-355 100 107.68 14 ±20.4 º Φ71    (50.8 × 50.8) 6.69 120 M85 × 1
f-100T-14-355B 100 135.475 14 ±21º Φ 70.7  (50 x 50) beam=14mm 5 120 M85 × 1
f-103T-355 103 136.13 12 ±20.4º Φ 72   (51 × 51) 5.58 100 M85 × 1
f-110T-355 110 153.88 8 ±24º Φ 92   (65 × 65) 8.9 120 M85 × 1
f-120T-355 120 149.107 10 ±22.5º Φ 92   (65 × 65) 8 118 M85 × 1
f-130T-355 130 159.92 10 ±19º Φ 85   (60 × 60) 8.45 120 M85 × 1
f-167T-10-355 167 211.25 10 ±24º Φ 127  (90 × 90) 10.8 130 M85 × 1
f-167T-14-355 167 234.52 14 ±18º Φ 99   (70 × 70) 7.8 140 M85 × 1
F-167T-14-355B 166.57 229.163 14 ±22º Φ 127  (90 × 90) 7.7 159 M85 × 1
f-175T-355 175 247.487 10 ±24º Φ 142  (101 × 101) 11.8 140 M85 × 1
f-295T-14-355 295 426.75 14 ±23.7º Φ244   (172 x 172) 13 280 M85 × 1
f-330T-355 330 581.581 14 ±20º Φ 245  (173 × 173) 15.3 270 M85 × 1
532nm Fuced Silica
Part Number EFL WD Φ in Scan Angle Scan Field Spot Size Φ Outside Max. IA Mount Thread
(mm) (mm) (mm) (mm) (mm) (µm) (mm) (°)
f-63T-510-550 63 82.1 10 ±16° Φ 33   (23 × 23) 6.2 90 1 M85 × 1
f-88T-14-510-550 88 100.63 14 ±17° Φ 52   (37 × 37) 10 120 1.9 M85 × 1
f-100T-510-550 100 142.2 10 ±20.7° Φ 76   (54 × 54) 13.5 120 0.38 M85 × 1
f-100T-14-510-550 100 135.402 14 ±21° Φ 70.7  (50 × 50) 7 120 1.3 M85 × 1
F-167T-14-510-550 167 232.23 14 ±21° Φ 127  (90 × 90) 11.61 140 3 M85 × 1
532nm Optical Glass
Part Number EFL WD Φ in Scan Angle Scan Field Spot Size ΦOutside Max. IA Mount Thread
(mm) (mm) (mm) (mm) (mm) (µm) (mm) (°)
f-100T-532 100 125.04 15 ±21.5° Φ 71   (50 × 50) 6.5 120 3.2 M85 × 1
f-110T-532 110 132.94 15 ±21.5° Φ 83   (60 × 60) 7.2 120 3.2 M85 × 1
f-170T-532 170 214.66 14 ±21.8° Φ 129  (91 × 91) 11.8 140 3 M85 × 1
f-170T-20-532 170 204.788 20 ±24° Φ 141 (100 × 100) 8.53 164 4 M102 × 1